HAT Current Sensors

LEM HAT Current Sensors are designed for accurate electronic measurement of DC, AC, and pulsed currents while ensuring galvanic isolation between the primary and secondary circuits. These sensors ensure efficient signal processing with an instantaneous voltage output of ±4V and a bipolar power supply requirement of ±15V. The HAT current sensors feature a 25kHz DC bandwidth that enables precise monitoring of dynamic current variations. These compact transducers support current measurements ranging from 200A to 1500A, making them ideal for high-power applications.

Sonuçlar: 16
Seçin Resim Parça Numarası Ürt. Açıklama Veri Sayfası Stok Durumu Fiyatlandırma (EUR) Tablodaki sonuçları sipariş verdiğiniz miktar uyarınca birim fiyata göre filtreleyin. Miktar RoHS ECAD Modeli Akım Oranı Sensör Tipi Tepki Süresi Kesinlik Frekans Aralığı
LEM Akım Sensörleri - Endüstriyel
1.5 kA Open Loop 5 us 1 % DC to 25 kHz
LEM Akım Sensörleri - Endüstriyel Current Transducer HAT 200 ... 1500-S For the electronic measurement of currents: DC, AC, pulsed,..., with galvanic separation between the primary circuit and the secondary circuit. 75Stokta Var
60Siparişte
Min.: 1
Çoklu.: 1

1 kA Open Loop 5 us 1 % 25 kHz
LEM Akım Sensörleri - Endüstriyel Current Transducer HAT 200 ... 1500-S For the electronic measurement of currents: DC, AC, pulsed,..., with galvanic separation between the primary circuit and the secondary circuit. 60Stokta Var
Min.: 1
Çoklu.: 1

400 A Open Loop 5 us 1 % 25 kHz
LEM Akım Sensörleri - Endüstriyel Current Transducer HAT 200 ... 1500-S For the electronic measurement of currents: DC, AC, pulsed,..., with galvanic separation between the primary circuit and the secondary circuit. 32Stokta Var
Min.: 1
Çoklu.: 1

600 A Open Loop 5 us 1 % 25 kHz
LEM Akım Sensörleri - Endüstriyel Current Transducer HAT 200 ... 1500-S For the electronic measurement of currents: DC, AC, pulsed,..., with galvanic separation between the primary circuit and the secondary circuit. 19Stokta Var
140Beklenen 31.03.2026
Min.: 1
Çoklu.: 1

800 A Open Loop 5 us 1 % 25 kHz
LEM Akım Sensörleri - Endüstriyel
1 kA Open Loop 5 us 1 % 25 kHz
LEM Akım Sensörleri - Endüstriyel
200 A Open Loop 5 us 1 % DC to 25 kHz
LEM Akım Sensörleri - Endüstriyel
200 A Open Loop 5 us 1 % DC to 25 kHz
LEM Akım Sensörleri - Endüstriyel Stokta Olmayan Ürün Teslimat Süresi 6 Hafta
Min.: 1
Çoklu.: 1
500 A Open Loop 5 us 1 % DC to 25 kHz
LEM Akım Sensörleri - Endüstriyel
500 A Open Loop 5 us 1 % DC to 25 kHz
LEM Akım Sensörleri - Endüstriyel
600 A Open Loop 5 us 1 % 25 kHz
LEM Akım Sensörleri - Endüstriyel
LEM Akım Sensörleri - Endüstriyel
750 A Open Loop 5 us 1 % DC to 25 kHz
LEM Akım Sensörleri - Endüstriyel
LEM Akım Sensörleri - Endüstriyel
LEM Akım Sensörleri - Endüstriyel